Sale
16A One Phase 3.5KW Fast Charging Portable EV Charger with 2 PCB Models
Original price was: $158.00.$107.00Current price is: $107.00.
Description
| CATEGO | PROJECT | SPECIFICATIONS | REMARK |
| APPEARANCE STRUCTURE |
Product Name | 7 kW single – phase AC charging pile main control board |
AC3073 |
| Product Size | 130*100* 40 ( L*W*H )mm | Main control board size | |
| Installation | Wall Mounted/F loor Mounted | Use with enclosures and accessories | |
| Main – board Weight | 210g | Only main control board | |
| ELECTRIC INDICATORS |
Input Voltage | 90-265V | Only the working voltage of the main board . T he power outputting need to modify, cooperate with the output over -voltage and under -voltage protection points |
| Input Frequency | 50/60Hz | ||
| Output Power | 7 kW MAX | ||
| Output Voltage | 175 -265V | C hange the outputting over -voltage and under – voltage protection points to output power |
|
| Output Frequency | 32A MAX | C hange the setting through the mini program and other independent modification, requiring the corresponding communication function |
|
| ENVIRONMENTAL INDICATORS |
A pplicable Scene | I ndoor/ Outdoor | Use with enclosures |
| Operation Temperature | -30?? ~ +55?? | ||
| Operation Humidity | 5% ~ 95% No Condensation | ||
| Operation A ltitude | <2000m | ||
| Cooling Method | Natural Cooling | ||
| Safety Standards | IEC61851. 1 | ||
| PROTECTION FOUNCTIONS |
over -voltage Protection | 265V | C hange the default setting independently through the mini program, requiring the corresponding communication function |
| under -voltage Protection | 175V | ||
| Over-current Protection | ≥ 110% Rated output | ||
| Leakage Protection | A + DC6mA or A | Two options are available | |
| Ground Protection | ? | C lose the default setting independently through the mini program, requiring the corresponding communication function |
|
| Over-temp Protection | 80?? | ||
| Lightning Protection | ? | ||
| COMMUNICATION METHODS |
Bluetooth | Optional | CBU -IPEX |
| Ethernet | Optional | ETH1 | |
| 4G | Optional | 4G1 – EN, Band: LTE FDD: B1/3/ 5/7/8/20 WCDMA: B1/ 5/8 GSM: B3/8 |
|
| Card Reader | Optional | ||
| HMI (H uman -computer interaction) |
Display Screen | Optional | 4 . 3 inch |
| LED I ndicator | According to enclosures | ||
| STARTING METHODS |
Swipe card, scan code, mini program, plug and charge, etc. |
According to the actual needs of customers and communication methods to achieve the requirements |
|
| INSULATION RESISTANCE |
I nput – Output I nput – Ground Output – Ground |
DC500V, 60S, ?? 10MΩ | The input L and N, and the output L and N are respectively short-circuited and tested |
| VOLTAGE RESISTANCE |
Ground | AC2000V, 60S, ?? 10mA | Test after the input L/N , and output L/ N are short- circuited. Remove the ground surge protection device before testing |